Typical Response Procedures for Company 2

 

Type of Alarm:

10-31 Structure Fire – House/Garage/Store Front

First truck to roll

FL-2

Typical Tasks to be performed

  1. Establish water supply from hydrant to truck
  2. Stretch attack line(s) from engine
  3. Forcible entry
  4. Establish lighting (if night time)

Equipment needed once on-scene

  • Hydrant connections
  • Air packs
  • Forcible entry and hand tools
  • Thermal Imaging Camera
  • Hose appliances
  • Water extinguisher

 

 

 

Type of Alarm:

10-31 Structure Fire – High or Mid rise building

First truck to roll

FL-2

Typical Tasks to be performed

  1. Establish water supply from hydrant to truck
  2. Connect to building standpipe system
  3.  

Equipment needed once on-scene

  • Hydrant connections
  • Hose to connect to standpipe
  • Apartment packs
  • Forcible entry and hand tools
  • Search ropes
  • Thermal Imaging Camera
  • Water extinguisher

 

 

 

Type of Alarm:

10-32 Vehicle Fire

First truck to roll

FL-2

Typical Tasks to be performed

  1. Stretch crosslays for attack lines
  2. Access hood compartment
  3. Access Trunk Compartment
  4. Establish water supply from hydrant to truck

Equipment needed once on-scene

  • Crosslays and front trash lines
  • Forcible entry tools

 

 

 

 

 

Type of Alarm:

10-33 Minor Fire/Trash/Brush Fire

First truck to roll

FL-2

Typical Tasks to be performed

  1. Stretch front trash line for attack
  2. Stretch Crosslay (if needed)

Equipment needed once on-scene

  • Front trash line
  • Hooks
  • Water extinguisher

 

 

 

Type of Alarm:

10-34 – Report of Smoke

First truck to roll

FL-2

Typical Tasks to be performed

Treat the same as a 10-31

Equipment needed once on-scene

Treat the same as a 10-31

 

 

 

Type of Alarm:

10-35 – Elevator entrapment

First truck to roll

FL-R

Typical Tasks to be performed

  1. Locate stuck elevator
  2. Shut off power to affected elevator car
  3. Remove trapped occupants

Equipment needed once on-scene

  • Elevator Keys
  • Collapsible ladder(s)
  • Utility rope

 

 

 

Type of Alarm:

10-35 – Extrication

First truck to roll

FL-R

Typical Tasks to be performed

  1. Perform scene assessment
  2. Stabilize vehicle
  3. Disconnect battery
  4. Perform extrication
  5. Establish lighting (if necessary)
  6. Remove occupant(s)

Equipment needed once on-scene

  • Cribbing and step chocks
  • Hydraulic spreader, cutter and ram
  • Cordless reciprocation saw
  • Windshield saw
  • Lighting equipment

 

 

 

Type of Alarm:

10-36 – Gas Leaks

First truck to roll

FL-R

Typical Tasks to be performed

  1. Attempt to locate source of odor
  2. Take air sample readings

Equipment needed once on-scene

  • Gas detector
  • Hand tools
  • Flashlights

 

 

 

Type of Alarm:

10-37 – Mutual Aid

First truck to roll

Depends On Request

Typical Tasks to be performed

Act as per request and type of alarm

 

 

 

Type of Alarm:

10-38 – Bomb Threat

First truck to roll

None usually

Typical Tasks to be performed

  • Respond to firehouse remain at firehouse unless otherwise instructed by command

 

 

 

Type of Alarm:

10-39 – Carbon Monoxide Alarm

First truck to roll

FL-R

Typical Tasks to be performed

  1. Attempt to locate source of alarm (check items that combust)
  2. Take air sample readings

Equipment needed once on-scene

  • Air Packs
  • Carbon monoxide detector
  • Hand tools
  • Flashlights

 

 

 

Type of Alarm:

10-45 – Active Alarm

First truck to roll

FL-2

Typical Tasks to be performed

  1. Attempt to locate source of alarm
  2. Reset Alarm

Equipment needed once on-scene

  • Air packs
  • Forcible entry and hand tools
  • Water extinguisher

 

 

 

Type of Alarm:

10-31- Second Alarm – Outside of Company 2 first Alarm Response

First truck to roll

FL-R

Typical Tasks to be performed

  1. Establish Air bottle changing station
  2. Establish FAST Team

Equipment needed once on-scene

  • Air bottles
  • Tarps
  • Forcible entry and hand tools
  • Search ropes
  • Thermal Imaging Camera
  • Water extinguisher
  • Hoses